Search results for "Electromagnetic shielding"

showing 10 items of 79 documents

Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors

2017

Abstract The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. A…

010302 applied physicsTest setupEngineeringReproducibilitybusiness.industry020208 electrical & electronic engineeringMechanical engineering02 engineering and technologyRepeatabilityVariance (accounting)01 natural sciencesReliability engineeringMetrology0103 physical sciencesElectromagnetic shielding0202 electrical engineering electronic engineering information engineeringRange (statistics)Measurement uncertaintybusinessInternational Journal of Electronics and Telecommunications
researchProduct

Antineutrino monitoring of spent nuclear fuel

2016

Military and civilian applications of nuclear energy have left a significant amount of spent nuclear fuel over the past 70 years. Currently, in many countries world wide, the use of nuclear energy is on the rise. Therefore, the management of highly radioactive nuclear waste is a pressing issue. In this letter, we explore antineutrino detectors as a tool for monitoring and safeguarding nuclear waste material. We compute the flux and spectrum of antineutrinos emitted by spent nuclear fuel elements as a function of time, and we illustrate the usefulness of antineutrino detectors in several benchmark scenarios. In particular, we demonstrate how a measurement of the antineutrino flux can help to…

010308 nuclear & particles physicsNuclear engineeringDetectorGeneral Physics and AstronomyFluxRadioactive wasteFOS: Physical sciences01 natural sciencesSpent nuclear fuel3. Good healthHigh Energy Physics - ExperimentOverburdenHigh Energy Physics - Experiment (hep-ex)High Energy Physics - PhenomenologyHigh Energy Physics - Phenomenology (hep-ph)0103 physical sciencesElectromagnetic shieldingEnvironmental scienceNeutrinoNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentLeakage (electronics)
researchProduct

Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.

2017

Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…

0106 biological sciencesbusiness.industryEquivalent dosemedicine.medical_treatmentBrachytherapyBrachytherapyPublic Health Environmental and Occupational HealthTreatment roomGeneral MedicineRadiation Dosage01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation ProtectionElectromagnetic shieldingCalibrationmedicineHumansScattering RadiationNuclear medicinebusinessRadiometryWaste Management and Disposal010606 plant biology & botanyJournal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.

2015

To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…

Adultmedicine.medical_specialtymedicine.medical_treatmentBrachytherapyBrachytherapyBiophysicsGeneral Physics and AstronomyFetal positionBreast NeoplasmsIonizing radiationLead shieldingBreast cancerFetusRadiation ProtectionPregnancymedicineHumansRadiology Nuclear Medicine and imagingRadiometrybusiness.industryRadiotherapy Planning Computer-AssistedRadiotherapy DosageGeneral Medicinemedicine.diseaseIridium RadioisotopesSurgeryRadiation therapyPregnancy ComplicationsElectromagnetic shieldingFemaleImplantbusinessNuclear medicinePhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct

Understanding the ring current effects on magnetic shielding of hydrogen and carbon nuclei in naphthalene and anthracene

2008

The local response to an external magnetic field normal to the molecular plane of naphthalene and anthracene was investigated via current density and magnetic shielding density maps. The Biot-Savart law shows that the deshielding caused by pi-ring currents in naphthalene is stronger for alpha- than for beta-protons due to geometrical factors. The shielding tensor of the carbon nuclei in both molecules is strongly anisotropic and its out-of-plane component determines the up-field chemical shift of (13)C in nuclear magnetic resonance spectra. The pi-ring currents flowing beyond the C-skeleton in front of a probe carbon nucleus, and on remote parts of the molecular perimeter, yield positive co…

AnthraceneHydrogennaphthalenechemistry.chemical_elementGeneral ChemistryAromatic ring currentMagnetic fieldComputational Mathematicschemistry.chemical_compoundchemistrycurrent density mapsElectromagnetic shieldingproton and carbon chemical shiftAtomic physicsnaphthalene; ring currents; proton and carbon chemical shift; current density mapsCarbonCurrent densityring currentsRing currentJournal of Computational Chemistry
researchProduct

Estimation of isotropic nuclear magnetic shieldings in the CCSD(T) and MP2 complete basis set limit using affordable correlation calculations

2013

A linear correlation between isotropic nuclear magnetic shielding constants for seven model molecules (CH2O, H2O, HF, F2, HCN, SiH4 and H2S) calculated with 37 methods (34 density functionals, RHF, MP2 and CCSD(T)), with affordable pcS-2 basis set and corresponding complete basis set results, estimated from calculations with the family of polarization-consistent pcS-n basis sets is reported. This dependence was also supported by inspection of profiles of deviation between CBS estimated nuclear shieldings and shieldings obtained with the significantly smaller basis sets pcS-2 and aug-cc-pVTZ-J for the selected set of 37 calculation methods. It was possible to formulate a practical approach o…

Basis (linear algebra)Computational chemistryAccurate estimationChemistryElectromagnetic shieldingIsotropyGeneral Materials ScienceGeneral ChemistryLimit (mathematics)Linear correlationCalculation methodsBasis setComputational physicsMagnetic Resonance in Chemistry
researchProduct

Orbital Decomposition of the Carbon Chemical Shielding Tensor in Gold(I) N-Heterocyclic Carbene Complexes.

2020

The good performance of N‐heterocyclic carbenes (NHCs), in terms of versatility and selectivity, has called the attention of experimentalists and theoreticians attempting to understand their electronic properties. Analyses of the Au(I)–C bond in [(NHC)AuL]+/0 (L stands for a neutral or negatively charged ligand), through the Dewar–Chatt–Duncanson model and the charge displacement function, have revealed that NHC is not purely a σ‐donor but may have a significant π‐acceptor character. It turns out, however, that only the σ‐donation bonding component strongly correlates with one specific component of the chemical shielding tensor. Here, in extension to earlier works, a current density analysi…

C-13 NMR-SPECTROSCOPYElectronic structureRING CURRENTS010402 general chemistry01 natural sciencesInorganic Chemistrychemistry.chemical_compoundDONATION Author InformationGROUP-11MAGNETIC-PROPERTIESTensorGold(I) NHC ComplexesFull Paper010405 organic chemistryChemistryLigandElectron donationCAPTIVE INTERMEDIATEFull PapersSymmetry (physics)0104 chemical sciencesChemical shielding tensorChemistryChemical physicsElectron back‐donationElectromagnetic shieldingElectron back-donationPATTERNSDiamagnetismDONATIONGoldCarbeneCurrent densityCarbene ligandsCONTINUOUS TRANSFORMATIONBONDAPPROXIMATIONEuropean journal of inorganic chemistry
researchProduct

Chemical Reaction Monitoring Using Zero-Field Nuclear Magnetic Resonance Enables Study of Heterogeneous Samples in Metal Containers

2020

Abstract We demonstrate that heterogeneous/biphasic chemical reactions can be monitored with high spectroscopic resolution using zero‐field nuclear magnetic resonance spectroscopy. This is possible because magnetic susceptibility broadening is negligible at ultralow magnetic fields. We show the two‐step hydrogenation of dimethyl acetylenedicarboxylate with para‐enriched hydrogen gas in conventional glass NMR tubes, as well as in a titanium tube. The low frequency zero‐field NMR signals ensure that there is no significant signal attenuation arising from shielding by the electrically conductive sample container. This method paves the way for in situ monitoring of reactions in complex heteroge…

Chemical substanceMaterials scienceHydrogenAnalytical chemistrychemistry.chemical_element010402 general chemistry01 natural sciencesChemical reaction7. Clean energyCatalysisNMR spectroscopyHyperpolarization (physics)Research Articleshyperpolarization010405 organic chemistryReaction MonitoringGeneral MedicineGeneral ChemistryNuclear magnetic resonance spectroscopyequipment and suppliesMagnetic susceptibility0104 chemical sciencesMagnetic fieldzero-fieldchemistryddc:540Electromagnetic shieldingResearch Article
researchProduct

Status of the EU DEMO HCLL breeding blanket design development

2018

International audience; In the framework of the European “HORIZON 2020” innovation and research programme, the EUROfusion Consortium develops a design of a fusion power demonstrator (DEMO). One of the key components in the fusion reactor is the Breeding Blanket (BB) surrounding the plasma, ensuring tritium self-sufficiency, heat removal for conversion into electricity, and neutron shielding. CEA-Saclay, with the support of Wigner-RCP and Centrum výzkumu Řež, is in charge of the development of one of the four BB concepts investigated in Europe for DEMO: the Helium Cooled Lithium Lead (HCLL) BB. The rationales of the HCLL are the use of Eurofer as structural material, eutectic liquid lithium-…

Computer scienceNuclear engineeringBlanketBreeding7. Clean energy01 natural sciences010305 fluids & plasmasTritium breeding ratio0103 physical sciencesGeneral Materials Science010306 general physicsDEMOSettore ING-IND/19 - Impianti NucleariCivil and Structural EngineeringBreeding BlanketHelium gasMechanical EngineeringFusion power[INFO.INFO-MO]Computer Science [cs]/Modeling and SimulationCoolantNuclear Energy and EngineeringElectromagnetic shieldingHCLLBlanketMaterials Science (all)Design evolution
researchProduct

Current density maps, magnetizability, and nuclear magnetic shielding tensors of bis-heteropentalenes. III. Thieno-thiophene isomers

2005

Near Hartree–Fock values of the magnetic susceptibility and nuclear magnetic shielding of bis-heteropentalenes consisting of two thiophene units ([2,3-b], [3,2-b], [3,4-b], and [3,4-c] isomers) have been estimated via computational schemes relying on continuous transformation of the origin of the current density within the coupled Hartree–Fock approximation and extended gaugeless Gaussian basis sets. The results are compared with those obtained via London gauge-including orbitals. Maps of streamlines and the modulus of the ring current density induced by a magnetic field normal to the molecular plane are reported for the three isomers of higher symmetry, showing that the intense diamagnetic…

Condensed matter physicsChemistryBiophysicsElectronCondensed Matter PhysicsMolecular physicsMagnetic susceptibilityCurrent density maps; magnetizability; nuclear magnetic shielding tensors; thieno-thiophene isomersMagnetic fieldchemistry.chemical_compoundMagnetic anisotropyElectromagnetic shieldingThiopheneDiamagnetismTensorPhysical and Theoretical ChemistryMolecular Biology
researchProduct